| TF-160 FOGGER (Fumigation and Hygiene) |
 |
|
|
|
| Used to apply disinfectant or detergent in 100m x 30m
(approx. 300' x 90') buildings |
The TF-160 is a convincing combination of experience, performance and a
highest standard of quality.
Teflon and Viton round off the high-quality appearance. Still manufactured by
hand so that every stage of production is checked in the subsequent stage. None of
the generators leave without a final inspection. This is a fundamental requirement
for the certification of the quality management system in accordance with DIN EN
ISO 9001 which was obtained in 1996.
See how the fogger works:
|
|
| Characteristics |
Accessories |
- Highest standard of quality: this is symptomatic for the complete
range of products. Only the best materials are used.
- The tank and rigid lines are made of stainless steel, guaranteeing
long operational reliability.
|
- You can order a device with either a 5 l or 60 l tank (and special
units can be connected to any size solutions tanks).
|
| Technical specifications of available models |
| |
TF-35 |
TF-W60 |
TF-95* |
TF-160* |
| Weight, empty in kg, approx. |
7,9 |
12,8 |
39,5 |
65 |
| Dimensions in cm LxWxH |
137,5x27x34 |
138x38x34 |
198x62x58 |
262x62x70 |
| Solution tank capacity in l |
5,7 or 10 |
5,7 or 10 |
60 |
60 |
| Fuel tank capacity in l |
1,2 |
2,5 |
5,5 |
10 |
| Fuel consumption in l/h, approx. |
2,0 |
3,6 |
4,0 |
9,0 |
| Performance** of combustion chamber in KW/HP |
18,7/25,4 |
33/45 |
36,8/50 |
82,2/112 |
| Average flow rate in l/h (oil), approx. |
20 |
- |
60 |
120 |
| Maximum flow rate in l/h of oil based formulations, approx. |
42 |
- |
100 |
160 |
| Flow rate with water in l/h approx. |
10 |
30 |
40 |
80 |
| Efficient horizontal reach in closed rooms using water and
carrier, i.e. "Nebol", in m, approx. |
40 |
60 |
60 |
120 |
| Efficient horizontal reach in closed rooms using water, in
m, approx. |
8 |
30 |
35 |
80 |
| Power supply |
4x1,5 V batteries LR6 (optional) |
4x1,5 V batteries LR6 (optional) |
4x1,5 V batteries LR20 |
12 V DC car-battery |
| Pressure in the solution tank in bar, approx. |
0,25 |
0,3 |
0,3 |
0,25 |
All generators are available as "W"-version for the
application of water based solutions also.
*These generators can be ordered without solution tank, but with
suction pump (12 V DC)!
**Theoretical value based on the energy of the consumed fuel. |
|
|
| Use |
| TF-160 fogger |
|
 |
|
|
|
|
|
|
|
|